How to select a suitable pipette ?

Posted by Admin | 19 Dec

The pipette tip is the most important factor affecting the accuracy of pipetting. The pipette tip and liquid handling/pipettor together form a complete pipette system.

 

Low adsorption pipette tip

The low adsorption pipette tip reduces the adsorption capacity of the sample by 3-5 times compared with the ordinary pipette tip. The special low-adsorption resin makes the inner surface of the pipette head more hydrophobic, which significantly reduces the loss of the samples due to adsorption and wall hanging. With lower liquid adsorption and a better pipetting effect. It is beneficial to save expensive reaction reagents, improve the accuracy of pipetting, and have no precipitation with 100% material inert.

 

Extended pipette tip

The extended suction tip allows you to reach the bottom of test tubes, reaction bottles, flasks, and other containers. Avoid the lower end of the pipette from touching the inner wall of the sample container, which not only increases the safety protection for the experimenter but also reduces the probability of sample cross-contamination.

 

Filter element suction head: The filter element can prevent accidental liquid splashing inside the pipette and avoid aerosol penetration into the pipette. Very suitable for genetic research, forensic science, PCR, and radioisotope sampling. Thermo fly provides two kinds of filter element suction heads: self-sealing and non-self-sealing filter element two kinds. The self-sealing suction tip prevents sample penetration and protects the pipette from damage or contamination by excessive inhalation.

 

Gel spot sample tip: A standard tip-like acrylamide or agarose gel is very time-consuming. Suitable for gel electrophoresis, and capillary sizing.

 

Solvent-safe carbon (filter element) suction head: The carbon fiber filter element is suitable for acid, alkali, and corrosive organic solvents. Is the best solution for the precision pipetting required for combinatorial chemistry? Strong acid, alkali, and corrosive organic solvents can cause damage to the pipette and cause serious errors. The innovative and active carbon fiber ART filter cartridge can prevent aerosol and vapor damage to the sample without affecting the accuracy and accuracy of the pipette.

 

Wide mouth suction head: Large open suction heads are ideal for genomic DNA, fragile cell lines, and other sticky material. The openings are 70% larger than standard heads, and they provide the flexibility needed to move difficult transfer samples. Designed specifically for researchers studying large molecules, such as genomic DNA, and is also ideal for transferring samples of fragile cell lines, such as macrophages, hybridoma cells, hepatocytes, etc. These samples are removed by using the standard suction head, and when the sample passes through the narrow hole of the standard suction head, it will cause the sample to be damaged by the mechanical shear force, causing cell damage and rupture. The use of a broad-mouth suction tip will increase the viability of the inoculated cells.

\